Limited Time SaleUS$69.49 cheaper than the new price!!
| Management number | 219350251 | Release Date | 2026/05/03 | List Price | US$46.33 | Model Number | 219350251 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
1. INTRODUCTIONPFR Series reactive power auto compensating controller is suitable for self-adjusting capacitor compensating devices in low voltage distribution system (hereinafter referred to as controller) and make power factor reach the presetting state by user to increase the utilization efficiency of power transformer, reduce line loss and improve voltage quality, thereby to increase the economic and social benefits.2. FUNCTION CHARACTERISTICS1.To calculate the input-cut capacitance by reactive power,with high precision compensation.2.Power factor has high precision measurement, with wide displaying range.3.Initial phase preset(homonymy terminal of software adjustment or current polarity).4. With friendly human-machine interface, easy to operate.5. All kinds of control parameters can be adjusted in whole digit. It is visual and easy to use.6. With two working modes: auto run and manual run.7. With protection function of over voltage and under voltage,8. With power down protection function, so data will not lose.9. With low current signal input impedance 0.01.3. SERVICE CONDITIONS1. Altitude does not exceed 2500m.2. Ambient environment:-25~+50.<;50% at 40 and90% at 20.4. There is no corrosive gas,conductive dust,combustivle explosive medium around.5. No severe vibration in installation place.4.DEBUGGINGWarning:During the process of adjustment,user should abide by the following adjustment steps. The one with (*) is the controller working under reactive power control mode.a. Assemble the compensating device according to the demand of connection diagram, and then make adetailed examination so as to remove the mistake that may cause serious potential safety hazard.b. Switching in compensating device,the controller enters into automatic state.*c. Input the transformation ratio ofat site signal current transformer, for the details see Parameter Preset.*d. Input the capacity of capacitor of each branch circuit, for the details see Parameter Preset.e. Operate "MENU" key to make indicator light of manual run shines. As one measure for debugging compensating device, manual run can be sued for checking its connection correet or not. Operate " key, one capacitor group input,and operate "" key, one capacitor group cut.Note:The output terminal,the capacitor value of which is zero,can't perform input and cut action.The above operation can be without current signal.f. In order to make the controller automatically input and cut capacitor group,besides user should put menu under menu of "Power factor" or "eactive power", the current signal should lag voltage signal, and the system voltage is not higher than over voltage protective value and is not lower than under voltage protective value.5.KEY FUNCTIONMenu key "MENU": Main menu and submenu for option. Note: Press menu key for 3s to enter into parameter preset menu.Increase key"": Preset parameter to increase the data, input capacitor group when for manual run.Decrease key"": Preset parameter to decrease the data, cut capacitor group when for manual run.Under menu"Power factor" display primary current A.Under menu"Reactive power" display voltage signal V.6.Parameter presetNote:When signa voltage signal and current signal input to the controller are on Positive polarity,user should adjust the parameter to"0"; When they are on Reverse polarity,user should adjust the parameter to"180"; If user can't judge polarity, off all load, then input one group or several groups capacitors,now the power factor that controller displayed is ncgativeand very low.If the power factor is not negative,it can be judged that the voltage signal and current signal are on Reverse polarity.If the initial phase is"180",user should adjust it to"0"and while itis"0",user should adjust it to"180", User should confirm this parameter correct or not after one controller is finished installation,or will cause the abnormal operation for controller.CT transformation ratio preset value is the numerator value of signal current transformer ratio.Eg.User's signal current transformer ratio is 500/5A,then the CT ratio preset value is 500,not is 100.The output loop capacitance should be preset to"O" if without connected with capacitor.The output loop controller will not oulput control signal if the preset capacitance of capacitor is"0",7.Input-cut principle1) When the capacitor bank can't input automatically, user should consider the following condition is tenable or not.It should be noted that the following conditions are necessary,must fulfil.a.Power factor value of system is lower than target power factor value.b.Over voltage indicator light doesn't light.c.We indicate active power of present electric network by P and reactive power by Q.target power factor by cos.Formula l must be tenable.2) When the power factor of electric nerwork is higher than target power factor, and the capacitor bank can't cut automatically, user should consider the following conditions is tenable or not.Use P to indicate the acuive power of electric network, Q to indicate reactive power of present electricc network and cos to indicate target power lactorl.Formula 2 must be tenable.8.Display instructionOver voltage: If the present menu indicator light flashes frequently, which means the controller works on overvolt thedisplay value is system voltage valueCos value: Displaying 0.985 means present power factor is lagging 0.985.Displaying-0.985 means present power facor is leading 0.985.Under current: Displaying "CO" means undercurrent, signal current is less than 50mA9. CONNECTION DIAGRAMOperating Voltage(Un):......380VOperating Frequency:........50/60Hz<;12VAOperating temperature:.....-20; to 50Current Measuring Range:..0.5mA-5A Measuring Accuracy:...........%±1%Current Transformer Ratio:....5/5A-9999/5AResponse Time:...............0.4sec. - 250sec.discharge Time:...............0.4sec. - 250secNumber of Steps:.............6 Steps;12 StepsConnection Type:.......Plug-in terminal connectionContact:........................3A/250VAC Resistive Load<;850gr.Panel Hole Sizes:..........140mm x 140mmProtection class:...........IP40<;2000 meter10.Connection DiagramPerforate dimension:144*144mm1,3 Voltage signal input terminal5,6 Incurrent signal input terminal23 Common terminal of control output terminal==========Rated Current : 0-5ARated Voltage : 380V 50/60HzOrigin : Mainland ChinaOperating Voltage(Un) : 380VOperating Frequency : 50/60Hz<;12VAOperating temperature : -20 to 50Current Measuring Range : 0.5mA-5AMeasuring Accuracy : %±1%Current Transformer Ratio : 5/5A-9999/5AResponse Time : 0.4sec. - 250sec.discharge Time : 0.4sec. - 250secNumber of Steps : 12 StepsConnection Type : Plug-in terminal connectionContact : 3A/250VAC Resistive Load<;850gr.Panel Hole Sizes : 140mm x 140mmMounting : Front panel mountingProtection class : IP40Operating Altitude :
| Item Weight | 1.76 ounces |
|---|---|
| Manufacturer | KZKNABLK |
| Item model number | KZKNABLK |
| Product Dimensions | 0.39 x 0.39 x 0.39 inches |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form